14-10
182582-1CD
182582-1CD
14 Description of Units and Circuit Boards
14.4Control Power Supply Unit (JZNC-YPS21-E)
MH900, DX200 Controller
Items Specifications
Input Rating Input Voltage: 200/220VAC
Voltage Fluctuation Range: +10% to -15% (170 to 242VAC)
Frequency: 50/60Hz ± 2Hz (48 to 62Hz)
Output Voltage DC + 5V
DC +24V (24V1: System, 24V2: I/O, 24V3: break)
Indicator
Control Power
ON/OFF
To turn ON the DX200 controller power, turn ON the non-fuse breaker of the
controller so that the control power supply is turned ON. If the controller is not located
at the workplace, the control power supply can be turned ON/OFF by an external
device, etc. after the non-fuse breaker of the controller is turned ON. It is operated by
the external switch connected with CN152 of the Control power supply unit as shown
in the following figure. (CN152-1 and CN152-2 are short-circuited when shipment)
Fig. 14-6: Connection to Control Power Supply Unit
See chapter 14.8 “Control Circuit Board (JANCD-YBK21-3E)” at page 14-43 for
wiring of CN152 connector.
DISPLAY Color Status
SOURCE Green Lights with power supply input.
Lights out when internal live part completes
discharge.
(Power supply status: being input)
POWER ON Green Lights when PWR_OK output signal is ON.
(Power supply status: being output)
+5V Red Lights with +5V over-current
(ON when abnormal)
+24V Red Lights with +24V over-current
(ON when abnormal)
FAN Red Lights when FAN error occurs.
OHT Red Lights when unit interior overheats
1
2
DX200
R-IN
R-INCOM
(JZNC-YPS21-E)
CN152
Remove the short-circuit positioner
Control Power Supply ON/OFF Switch
Control power supply unit