EasyManuals Logo

YASKAWA V1000 Technical Manual

YASKAWA V1000
480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #458 background imageLoading...
Page #458 background image
No. Name
User
Setting
C3-04
Slip Compensation Selection during
Regeneration
C3-05 Output Voltage Limit Operation Selection
C4-01 Torque Compensation Gain
C4-02 Torque Compensation Primary Delay Time
C4-03 Torque Compensation at Forward Start
C4-04 Torque Compensation at Reverse Start
C4-05 Torque Compensation Time Constant
C4-06 Torque Compensation Primary Delay Time 2
C5-01
ASR Proportional Gain 1 (for Simple PG V/f
Control)
C5-02
ASR Integral Time 1 (for Simple PG V/f
Control)
C5-03
ASR Proportional Gain 2 (for Simple PG V/f
Control)
C5-04
ASR Integral Time 2 (for Simple PG V/f
Control)
C5-05 ASR Limit (for Simple PG V/f Control)
C6-01 Duty Mode Selection
C6-02 Carrier Frequency Selection
C6-03 Carrier Frequency Upper Limit
C6-04 Carrier Frequency Lower Limit
C6-05 Carrier Frequency Proportional Gain
d1-01 Frequency Reference 1
d1-02 Frequency Reference 2
d1-03 Frequency Reference 3
d1-04 Frequency Reference 4
d1-05 Frequency Reference 5
d1-06 Frequency Reference 6
d1-07 Frequency Reference 7
d1-08 Frequency Reference 8
d1-09 Frequency Reference 9
d1-10 Frequency Reference 10
d1-11 Frequency Reference 11
d1-12 Frequency Reference 12
d1-13 Frequency Reference 13
d1-14 Frequency Reference 14
d1-15 Frequency Reference 15
d1-16 Frequency Reference 16
d1-17 Jog Frequency Reference
d2-01 Frequency Reference Upper Limit
d2-02 Frequency Reference Lower Limit
d2-03 Master Speed Reference Lower Limit
d3-01 Jump Frequency 1
d3-02 Jump Frequency 2
d3-03 Jump Frequency 3
d3-04 Jump Frequency Width
d4-01
Frequency Reference Hold Function
Selection
d4-03 Frequency Reference Bias Step (Up/Down 2)
d4-04
Frequency Reference Accel/Decel (Up/Down
2)
d4-05
Frequency Reference Bias Operation Mode
Selection (Up/Down 2)
d4-06 Frequency Reference Bias (Up/Down 2)
No. Name
User
Setting
d4-07
Analog Frequency Reference Fluctuation
Limit (Up/Down 2)
d4-08
Frequency Reference Bias Upper Limit (Up/
Down 2)
d4-09
Frequency Reference Bias Lower Limit (Up/
Down 2)
d4-10
Up/Down Frequency Reference Limit
Selection
d7-01 Offset Frequency 1
d7-02 Offset Frequency 2
d7-03 Offset Frequency 3
E1-01 Input Voltage Setting
E1-03 V/f Pattern Selection
E1-04 Max Output Frequency
E1-05 Max Voltage
E1-06 Base Frequency
E1-07 Mid Output Frequency
E1-08 Mid Output Frequency Voltage
E1-09 Minimum Output Freq.
E1-10 Minimum Output Freq. Voltage
E1-11 Mid Output Frequency 2
E1-12 Mid Output Frequency Voltage 2
E1-13 Base Voltage
E2-01 Motor Rated Current
E2-02 Motor Rated Slip
E2-03 Motor No-Load Current
E2-04 Number of Motor Poles
E2-05 Motor Line-to-Line Resistance
E2-06 Motor Leakage Inductance
E2-07 Motor Iron-Core Saturation Coefficient 1
E2-08 Motor Iron-Core Saturation Coefficient 2
E2-09 Motor Mechanical Loss
E2-10 Motor Iron Loss for Torque Compensation
E2-11 Motor Rated Output
E2-12 Motor Iron-Core Saturation Coefficient 3
E3-01 Motor 2 Control Method Selection
E3-04 Motor 2 Max Output Frequency
E3-05 Motor 2 Max Voltage
E3-06 Motor 2 Base Frequency
E3-07 Motor 2 Mid Output Frequency
E3-08 Motor 2 Mid Output Frequency Voltage
E3-09 Motor 2 Minimum Output Freq
E3-10 Motor 2 Minimum Output Freq. Voltage
E3-11 Motor 2 Mid Output Freq. 2
E3-12 Motor 2 Mid Output Freq. Voltage 2
E3-13 Motor 2 Base Voltage
E4-01 Motor 2 Rated Current
E4-02 Motor 2 Rated Slip
E4-03 Motor 2 Rated No-Load Current
E4-04 Motor 2 Motor Poles
E4-05 Motor 2 Line-to-Line Resistance
E4-06 Motor 2 Leakage Inductance
E4-07
Motor 2 Motor Iron-Core Saturation
Coefficient 1
E.3 User Setting Table
458
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual

Table of Contents

Other manuals for YASKAWA V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 and is the answer not in the manual?

YASKAWA V1000 Specifications

General IconGeneral
Input Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Frequency0-400 Hz
Control MethodV/f control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication OptionsModbus RTU
Ambient Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20°C to +65°C (-4°F to 149°F)
Humidity95% (non-condensing)
Cooling MethodForced Air Cooling
EnclosureIP20