No. Name
User
Setting
r1-26 DWEZ Connection Parameter 13 (lwr.)
r1-27 DWEZ Connection Parameter 14 (upr.)
r1-28 DWEZ Connection Parameter 14 (lwr.)
r1-29 DWEZ Connection Parameter 15 (upr.)
r1-30 DWEZ Connection Parameter 15 (lwr.)
r1-31 DWEZ Connection Parameter 16 (upr.)
r1-32 DWEZ Connection Parameter 16 (lwr.)
r1-33 DWEZ Connection Parameter 17 (upr.)
r1-34 DWEZ Connection Parameter 17 (lwr.)
r1-35 DWEZ Connection Parameter 18 (upr.)
r1-36 DWEZ Connection Parameter 18 (lwr.)
r1-37 DWEZ Connection Parameter 19 (upr.)
r1-38 DWEZ Connection Parameter 19 (lwr.)
r1-39 DWEZ Connection Parameter 20 (upr.)
r1-40 DWEZ Connection Parameter 20 (lwr.)
T1-00 Motor Selection 1/2
T1-01 Auto-Tuning Mode Selection
T1-02 Motor Rated Power
T1-03 Motor Rated Voltage
T1-04 Motor Rated Current
T1-05 Motor Base Frequency
T1-06 Number of Motor Poles
No. Name
User
Setting
T1-07 Motor Base Speed
T1-11 Motor Iron Loss
U6-80 Option Monitor 1
U6-81 Option Monitor 2
U6-82 Option Monitor 3
U6-83 Option Monitor 4
U6-84 Option Monitor 5
U6-85 Option Monitor 6
U6-86 Option Monitor 7
U6-87 Option Monitor 8
U6-88 Option Monitor 9
U6-89 Option Monitor 10
U6-90 Option Monitor 11
U6-91 Option Monitor 12
U6-92 Option Monitor 13
U6-93 Option Monitor 14
U6-94 Option Monitor 15
U6-95 Option Monitor 16
U6-96 Option Monitor 17
U6-97 Option Monitor 18
U6-98 Option Monitor 19
U6-99 Option Monitor 20
E.3 User Setting Table
462
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual

Table of Contents

Other manuals for YASKAWA V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 and is the answer not in the manual?

YASKAWA V1000 Specifications

General IconGeneral
Input Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Frequency0-400 Hz
Control MethodV/f control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication OptionsModbus RTU
Ambient Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20°C to +65°C (-4°F to 149°F)
Humidity95% (non-condensing)
Cooling MethodForced Air Cooling
EnclosureIP20