E4: Motor 2 Parameters .............................................................................................................168
E5: PM Motor Settings ...............................................................................................................170
5.6 F: Option Settings ....................................................................................................... 173
F1: Error Detection for V/f Control with PG ................................................................................173
F6: Serial Communications Option Card Settings......................................................................174
CC-Link Parameters...................................................................................................................175
MECHATROLINK-II Parameters ................................................................................................175
MECHATROLINK-III Parameters
...............................................................................................175
PROFIBUS-DP Parameters .......................................................................................................175
CANopen Parameters ................................................................................................................175
CompoNet Parameters...............................................................................................................175
DeviceNet Parameters ...............................................................................................................175
5.7 H: Terminal Functions................................................................................................. 176
H1: Multi-Function Digital Inputs ................................................................................................176
H2: Multi-Function Output ..........................................................................................................186
H3: Multi-Function Analog Input Terminals ................................................................................195
H4: Multi-Function Analog Output Terminals .............................................................................200
H5: MEMOBUS/Modbus Serial Communication ........................................................................ 201
H6: Pulse Train Input/Output......................................................................................................201
5.8 L: Protection Functions .............................................................................................. 203
L1: Motor Protection Functions ..................................................................................................203
L2: Momentary Power Loss Ride-Thru.......................................................................................207
L3: Stall Prevention ....................................................................................................................210
L4: Speed Agree/Frequency Reference Loss Detection ............................................................ 216
L5: Fault Restart.........................................................................................................................220
L6: Torque Detection..................................................................................................................221
L7: Torque Limit .........................................................................................................................223
L8: Hardware Protection.............................................................................................................224
5.9 n: Special Adjustments............................................................................................... 229
n1: Hunting Prevention...............................................................................................................229
n2: Automatic Frequency Regulator (AFR) Tuning ....................................................................229
n3: High Slip Braking (HSB)/Overexcitation Deceleration..........................................................230
n6: Motor Line-to-Line Resistance Online Tuning ......................................................................231
n8: PM Motor Control .................................................................................................................232
5.10 o: Operator Related Settings...................................................................................... 235
o1: Display Settings and Selections ...........................................................................................235
o2: Operator Key Selections ......................................................................................................236
o3: Copy Function ......................................................................................................................238
o4: Maintenance Monitor Settings..............................................................................................238
q: DriveWorksEZ Parameters.....................................................................................................240
r: DriveWorksEZ Connection Parameters .................................................................................. 240
T: Motor Tuning ..........................................................................................................................240
5.11 U: Monitor Parameters................................................................................................ 241
U1: Operation Status Monitors ...................................................................................................241
U2: Fault Trace...........................................................................................................................241
U3: Fault History.........................................................................................................................241
U4: Maintenance Monitors .........................................................................................................241
U5: PID Monitors ........................................................................................................................241
U6: Control Monitors ..................................................................................................................241
U8: DriveWorksEZ Monitors.......................................................................................................241
6. TROUBLESHOOTING......................................................................................243
6.1 Section Safety.............................................................................................................. 244
6.2 Motor Performance Fine Tuning ................................................................................ 246
Table of Contents
6
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual

Table of Contents

Other manuals for YASKAWA V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 and is the answer not in the manual?

YASKAWA V1000 Specifications

General IconGeneral
Input Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Frequency0-400 Hz
Control MethodV/f control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication OptionsModbus RTU
Ambient Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20°C to +65°C (-4°F to 149°F)
Humidity95% (non-condensing)
Cooling MethodForced Air Cooling
EnclosureIP20