EasyManuals Logo

YOKOGAWA ADMAG TI Series User Manual

YOKOGAWA ADMAG TI Series
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #178 background imageLoading...
Page #178 background image
<6. Parameter Lists>
177
IM 01E21A02-03EN
6.2 Sensor Transducer Block
 List of sensor transducer block parameter
Relative
Index
Index Parameter Name Default Value
Write
Mode
Description
0 2000 Block Header STB O/S
Information on this block, such
as Block Tag, DD Revision,
Execution, etc.
1 2001 ST_REV 0 -
Represents the revision level of
the setting parameter of the own
block. This revision is updated if
the setpoint is changed. Used to
check for parameter change, etc.
2 2002 TAG_DESC Space(32characters) AUTO
Universal parameter to store a
comment explaining tag contents.
3 2003 STRATEGY 1 AUTO
Universal parameter intended to
be used for the high-level system
to separate function blocks.
4 2004 ALERT_KEY 1 AUTO
Keyinformationtoidentifywhere
an alert takes place. Generally,
this parameter is used by the high-
levelsystemtoidentifyspecic
areas in a plant that are under
thecontrolofspecicoperators,
to separate necessary alerts
only. This is one of the universal
parameters.
5 2005 MODE_BLK
0x80(O/S)
0x80(O/S)
0x88(Auto,O/S)
0x08(Auto)
AUTO
-
AUTO
AUTO
Universal parameter to show a
block operation state. Consists of
Actual mode, Target mode, Permit
mode and Normal mode.
6 2006 BLOCK_ERR 0x0000 -
Indicates the error statuses related
to the own block.
7 2007 UPDATE_EVT
0(Uninitialized)
0(Uninitialized)
0,0
0
0
AUTO
-
-
-
-
Indicates contents of the event
whenanupdateevent(achange
tothesetpoint)occurs.
8 2008 BLOCK_ALM
0(Uninitialized)
0(Uninitialized)
0,0
0(Other)
0
AUTO
-
-
-
-
Indicates contents of the alarm
when a block alarm occurs.
9 2009
TRANSDUCER_
DIRECTORY
1
2010
-
-
Parameter to store the index of the
transducer included in the device.
10 2010
TRANSDUCER_
TYPE
32872(SensorTB) - Indicates the device type.
11 2011
TRANSDUCER_
TYPE_VER
0x0001 - Indicates the version of the device.
12 2012 XD_ERROR 0 -
Stores XD_ERROR which is
occurring in the sensor transducer
block.
13 2013
COLLECTION_
DIRECTORY
0 -
Stores indexes of important
parameters in the transducer
block and the item ID of the
corresponding DD.
14 2014
PRIMARY_
VALUE_TYPE
101(volumetric) -
Indicates a process type of
Primary Value.
15 2015 PRIMARY_VALUE
0
0
-
-
Indicatesthevolumetricowrate.

Table of Contents

Other manuals for YOKOGAWA ADMAG TI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA ADMAG TI Series and is the answer not in the manual?

YOKOGAWA ADMAG TI Series Specifications

General IconGeneral
BrandYOKOGAWA
ModelADMAG TI Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals