<Appendix 2. Integrator (It) Block>
251
IM 01E21A02-03EN
A2.7 List of Integrator Block Parameters
Index
Parameter
Name
Default
Value
Write
Mode
View
Description
1 2 3 4
0
BLOCK_
HEADER
TAG:“IT”
Block
Tag=o/s
Information relating to this function block, such
as block tag, DD revision, execution time
1 ST_REV 0 --- 2 2 2 2
The revision level of the set parameters
associated with the Integrator block
2 TAG_DESC Nu11 --- Stores comments describing tag information.
3 STRATEGY 1 2
Thestrategyeldisusedbythehigh-level
system to identify the function block.
4 ALERT_KEY 1 1
Keyinformationusedtoidentifythelocationat
which an alert occurred
5 MODE_BLK 4 4
Integrator block mode. O/S, MAN, and AUTO
are supported.
6 BLOCK_ERR --- 2 2
Indicates the active error conditions
associated with the function block in bit
strings.
7 TOTAL_SP 1000000.0 4 4
The target value of an integrated value or a
start value for counting down
8 OUT MAN 5 5 Output
9 OUT_RANGE
1000000.0
11
Setsscalingforoutputdisplay.Doesnota󰀨ect
the block operation. For note.
0.0
m3(1034)
0
10
GRANT_
DENY
0 2
The parameter for checking if various
operations have been executed
11
STATUS_
OPTS
0 OS 2
Allows you to select a status-related option.
The Integrator block uses “Uncertain if Man
mode”only.
12 IN_1 0.0 5 5
Inputsowrate(RATE,ACCUM)signalsfrom
the AI block or PI block.
13 IN_2 0.0 5 5
14 OUT_TRIP 0 2 2
An output parameter informing the user that
the integrated value has exceeded the target
value
15 OUT_PTRIP 0 2 2
An output parameter informing the user that
the integrated value is reaching the target
value
16 TIME_UNIT1 sec(1) MAN 1
SpeciesthetimeunitoftheRATE(kg/s,
lb/min,kg/h...etc.)ofthecorrespondingIN.
17 TIME_UNIT2 sec(1) MAN 1
18 UNIT_CONV 1.0 4
Speciestheunitconversionfactorfor
standardizing the unit of IN_2 into that of IN_1.
19 PULSE_VAL1 1.0 MAN 4
Speciesthefactorforconvertingthenumber
of pulses for the corresponding IN into an
appropriate engineering unit.
20 PULSE_VAL2 1.0 MAN 4
21 REV_FLOW1 0 2 2
Selectorswitchusedtospecifytheuidow
direction(forward/reverse)withrespecttothe
corresponding IN
22 REV_FLOW2 0 2 2
23 RESET_IN 0 2 2
The parameter that receives a reset request
from an external block to reset the integrated
values
24 STOTAL 0.0 4
Indicates the snapshot of OUT just before a
reset.
25 RTOTAL 0.0 MAN 4 4
Indicates the integrated value of the absolute
values of the increments if the input status is
“Bad”.
26 SRTOTAL 0.0 4
Indicates the snapshot of RTOTAL just before
a reset.
27 SSP 0.0 4
Indicates the snapshot of TOTAL_SP just
before a reset.

Table of Contents

Other manuals for YOKOGAWA ADMAG TI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA ADMAG TI Series and is the answer not in the manual?

YOKOGAWA ADMAG TI Series Specifications

General IconGeneral
BrandYOKOGAWA
ModelADMAG TI Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals