EasyManuals Logo

YOKOGAWA MW100 User Manual

YOKOGAWA MW100
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
3-43
IM MW100-01E
Setting and Data acquisiton
3
3.12 Starting and Stopping Measurement,
Computation, and Recording
This is an explanation of the procedure for starting and stopping measurement,
computation, and recording. These operations can be performed by pressing keys on the
MW100 main module, or from a browser.
The state transition diagram of the MW100 is given below.
Setting
Recording
Measurement
Computation*
* On models with the /M1 option
Setting Mode
Measurement Mode
Hold down
for 2 s
Hold down
for 2 s
Hold down
for 2 s
Hold down
for 2 s
Starting and Stopping Measurement
Using Main Module Keys
• Starting Measurement
While measurement is stopped, briefly press the START key. Measurement starts
and the unit switches to Measurement mode.
• Stopping Measurement
While recording and computation are stopped, briefly press the STOP key.
Measurement stops and the unit switches to Setting mode.
Using a Browser
• Starting Measurement
In the Status table in the top screen, select Start from the Operation list under the
Measurement item. Measurement starts and the unit switches to Measurement mode.
• Stopping Measurement
In the Status table in the top screen, select Stop from the Operation list under the
Measurement item. Measurement stops and the unit switches to Setting mode.