Monitoring Control of Alarmed Conditions
13-8 User Manual ML700
Field
Description
Direction (Dir)
Direction related to the event. Possible values are:
TRMT — the component was transmitting
RCV — the component was receiving
BTH — the component was transmitting and receiving
NA — Not Applicable
About Alarm Severity and Conditions
Table 63: Alarm and Severity Conditions
CR
(Critical Alarm)
Critical indicates that a severe, usually service-affecting condition has occurred
and that immediate corrective action is imperative, regardless of the time of day or
day of the week.
MJ
(Major Alarm)
Major is used for hardware or software conditions that indicate a serious disruption
of service or the malfunctioning or failure of important circuits. These troubles
require the immediate attention and response of a craft person to restore or
maintain system capability. The urgency is less than in critical situations because
of a lesser immediate or impending effect on service or system performance.
MN
(Minor Alarm)
Minor is used for troubles that do not have a serious effect on service to customers
or for troubles in circuits that are not essential to system operations.
NA
(Not Alarmed)
The Not Alarmed condition is not reported as an alarm. It can be viewed as a NA
condition in the Alarms and Condition tables in the appropriate views.
NR
(Not Reported)
The Not Reported condition is not reported at all and does not appear in the
Alarms and Condition tables.
CL
(Cleared Alarm)
The Cleared Alarm notification code appears only in the Alarm History table in
the Alarms pane indicating clearance of an alarm.