Appendix I - Recommended Actelis MiTOP Configuration Parameters MiTOP Applications Parameters
MiTOP Applications Parameters
Table 117: MiTOP Applications Configuration
Configuration >
Applications > Multiservice
over PSN > Peer
Set the Peer site name
(description).
Set Peer IP Address.
In case of redundant system:
Two MiTOP units share the
same interface via Y-cable –
both units should have the
same MGMT IP.
Two MiTOP units connected to
parallel cables – different
MGMT IP should be provided
for each unit.
Peer MAC IP Address, usually
discovered automatically by
ARP running on SFP.
Configuration >
Applications > Multiservice
over PSN > PW
Defining a Pseudowire
Connection.
Set the reasons for counting
discarded frames.
Only valid value is SAToP.
Configuration >
Applications > Multiservice
over PSN > PW > General
Parameters
Set the source IP for PW traffic
(different from MGMT host IP).
Set the PSN Type (UDP/IPv4,
MPLS, MEF).
Only valid value is Manually.
Defines OAM functionality.
Defines Mitop operation in
case of unreachable
destination.
Define UDP source and
destination ports.