SNMP Agent and Trap Parameters Management Configuration
ML700 User Manual 3-19
2. Under Trap Type Definitions, select the Trap Source OID as one of the following:
MIB - traps displayed according to their MIB source
Enterprise - traps displayed according to the ML source
3. To allow Traps/Notifications from Standard MIBs only:
Press Enable All button
Disable Actelis Alarm MIB notifications and click OK.
4. To allow Traps/Notifications from Actelis proprietary MIB:
Press Disable All button
Enable Actelis Alarm MIB notifications and click OK.
Optionally, enable Bridge MIBs and click OK.
SNMP Traps from Non-IP CPEs
ML700 CPE that is not assigned an IP (hosted by an IP-based CO NE) sends SNMP
notifications using the IP address of the host CO NE.
All configurations of SNMP Agent/Trap Destination provided on non-IP NE are used by the
ML to originate the trap, although CO NE IP address is attached when trap frame is sent to
the Management plane thought CO NE.
To identify original source of a non-IP CPE in SNMP v1 trap, the following fields can be
used
Agent Address: <CO IP address>, < “don’t care” value of UDP SA auto-set by CO> , <CPE
SMNP Version>
Community: <COMSTR configured on CPE>@<CPE-TID%CO-HSL-AID>
SNMPv1 agent address: 0.0.0.0
To identify original source of a non-IP CPE in SNMP v2c trap, the following fields can be
used
Agent Address: <CO IP address>, <“don’t care” value of UDP SA auto-set by CO> , <CPE
SNMP Version>
Community: <COMSTR configured on CPE>@<CPE-TID%CO-HSL-AID>