Appendix C - Step-by-Step Commissioning Procedures ML CO - Administration Configuration
C-6 User Manual ML700
ML CO - Administration Configuration
The following steps enable remote Management Access and the configure security policy.
Implement this procedure for all units, starting from the most remote ML device, to avoid
Management LAN connectivity loss during configuration.
NOTE: Use a local CRAFT port connection to avoid Management LAN connectivity loss during
configuration.
1. Set System ID to provide unique identification of System and its location for managing
via TL1 (applied as TID) and SNMP (applied as System Name) interfaces. TL1 and
SNMP identification can be applied equally or differently. By factory setup, each ML
device Serial Number is reported as TID/System Name.
2. Set Date and Time (manually or enable SNTP) to provide correct timestamp of alarm
conditions reported from the Actelis systems.
3. Configure Management LAN connectivity according to installed Ethernet Service traffic
topology and use guidelines for MGMT traffic in various topologies, see L2 Network
Configuration in Various Topologies (on page G-1).
4. Set User Accounts. Enable Password control (complexity, history, failed login, etc.), if
required by Provider Management access policy.
5. If required, configure SSH and ACL according to Provider Management access policy.
6. If required, block non-IP access on ML device installed on CO to avoid insecure access
to CO NE from remote NEs.