Monitoring Error Counters, Measurements and Threshold Alerts
Error Counters, Measurements and
Threshold Alerts
The MetaASSIST View provides a set of functions and capabilities necessary for the system
to gather and store a range of counters associated with parameters monitored over the
network. These counters enable systematic monitoring of the ML device through continuous
collection and analysis. The counters are accumulated over pre-determined accumulation
periods (15-minutes and 1-day) and maintained in designated storage counters. Additional
counters are provided to maintain a recent history of the parameters as follows:
Up to 32 (15 minute) Historic counters are supported (in addition to the current 15 min
counter)
Up to seven (single day) Historic counters are supported (in addition to the Current single
day counter)
In addition, threshold alerts are generated in case PM counter crossed a pre-configured
threshold value.
These monitoring options are accessed via the PM Operations Pane (on page 13-13). The
pane is available for various items (e.g. MEP) The pane options differ depending on the
element.