General Safety Summary
1. Read and follow all warning notices and instructions marked on this product or included in this
manual.
2. All installation, repair or replacement procedures must be performed by qualified service
personnel.
3. Before attempting to operate or repair this product, make sure product is properly grounded.
4. This product uses an external power source. Do not touch exposed connections, components or
wiring when power is present.
5. Do not operate this product with panels removed or with suspected failure or damage to
electrical components.
6. Do not operate or repair this product in wet or damp conditions or in an explosive atmosphere.
7. Keep product surfaces clean and dry.
8. Provide proper ventilation.
9. Observe all ratings and markings on the product. Before making connections to the product,
consult the appropriate chapters of this manual for further ratings information.
10. Many of the cables for this product are supplied by Actelis Networks. Cables that are supplied by
the customer must comply with the regulatory inspection authorities and are the responsibility of
the customer. To reduce the risk of fire, make sure all cables are UL Listed or CSA Certified.
11. This equipment must be installed according to country national electrical codes. For North
America, equipment must be installed in accordance with the US National Electrical Code, Articles
110–16, 110–17 and 110–18 and the Canadian Electrical Code, Section 12. If necessary, consult
with the appropriate regulatory agencies and inspection authorities to ensure compliance.
12. Over-current Protection: It is recommended to incorporate in the building wiring, a readily
accessible listed branch circuit overcurrent protective device rated to 2A min. and 5A max. A 5A
circuit over current protective device can feed two ML700 units in rack mount sleeve.
13. The equipment shall be connected to a properly earthed supply system.
14. All equipment in the immediate vicinity shall be earthed the same way and shall not be earthed
elsewhere.
15. A disconnect device is not allowed in the earthed circuit between the DC supply source and the
frame/earthed circuit connection.
16. When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never
look directly at the fiber TX port and fiber cable ends when they are powered on.
17. In case of Fan alarm (HWFLT), it is required to replace ML700 within four (4) hours.
Prevention of Electrostatic Discharge (ESD) Damage
1. When working with electronic components, wear a commonly grounded antistatic wrist strap to
discharge the static voltage from your body in accordance with approved standards.
2. Do not use any devices capable of generating or holding a static charge in the work area where you
install or remove electronic components. Avoid handling electronic components in areas that have a