*Can’t find calibration program file* (–426)
Explanation: While processing a CALIBRATE command or instruction, the V
+
system could not find the calibration utility program on the file
CAL_UTIL.V2.
User action: Restore the missing file from the V
+
distribution disk to the direc-
tory \CALIB\ on the local drive or working system disk.
*Can’t go on, use EXECUTE or PRIME* (–313)
Explanation: An attempt has been made to continue the execution of a program
that has completed or stopped because of a HALT instruction. Nor-
mally, an error results when a PROCEED, RETRY, or XSTEP com-
mand is entered (or the pendant RUN/HOLD button is pressed)
after a program has completed all its cycles.
User action: Use the EXECUTE or PRIME command, or the pendant PRIME
function, to restart the program from the desired instruction.
*Can’t interpret line* (–450)
Explanation: V
+
could not interpret the last command or instruction entered.
User action: Check the spelling and usage, and reenter the line. In the case of an
error while loading from the disk, edit the affected programs to cor-
rect the indicated lines—they have been converted to bad lines.
*Can’t mix MC & program instructions* (–414)
Explanation: A program instruction has been encountered during processing of a
command program, or an MC instruction has been encountered in a
normal program.
User action: Edit the command program to use the DO command to include the
program instruction, or remove the MC instruction from the normal
program.
*Can’t open vision window for read/write* (–734)
Explanation: An attempt has been made to open the vision window in read/write
mode, but the vision system is performing some critical processing
that precludes it from releasing the window.
User action: Change the program to have it try the FOPEN again later, or specify
/WRITEONLY if no reading will be performed.