  9
*No objects seen* (–704)
Explanation: The vision system reports that no objects were seen, in response to a
VTRAIN or VLOCATE command. In the VLOCATE case, it is an
error only if you expect to see objects.
User action: In the training case, make sure the training object is visible under
the camera. If you expect to see objects, check the threshold parame-
ter, the minimum area parameter, and the camera hardware.
*No other program referenced* (–353)
Explanation: A command was issued that attempted to reference a previously
edited program, but no other program has been edited during the
current editing session.
User action: Use the New or GoTo function-key command (or the N keyboard
command) to change to a new program.
*No picture data available* (–723)
Explanation: A vision operation was attempted that requires processed picture
data (run-length encodings) when no processed picture data was
available.
User action: Issue a VPICTURE or VWINDOW command or instruction with a
mode parameter of 1 or 1. This will provide the processed picture
data needed for rulers or reprocessing.
*No program specified* (–301)
Explanation: No program was specified for an EXECUTE or SEE command or
instruction, or DEBUG command, and no previous program is avail-
able as a default.
User action: Type the line again, providing a program name.
*No prototypes* (–702)
Explanation: This is the response to the monitor commands VSTORE and
VSHOW (without a parameter) when no prototypes currently exist.
User action: Load some vision object prototypes or train a new one.