*RSC reset* (–652)
Explanation: V
+
has detected that the robot signature card (RSC) has lost power
temporarily, but is now functioning.
User action: Turn high power back on and resume program execution. If the
problem persists, check the cabling to the robot. Contact Adept Cus-
tomer Service if no solution can be found.
*RSC time-out* (–653)
Explanation: V
+
has not received a response from the robot signature card (RSC)
when expected, during the initial calibration data load. The RSC or
its cabling is probably faulty.
User action: Power down the controller and check the cables to the robot. If the
problem persists, contact Adept Customer Service.
*RSC transmission garbled* (–654)
Explanation: V
+
has received an invalid transmission from the robot signature
card (RSC). Either a hardware problem has occurred or the robot is
being operated in an environment with excessive electrical noise.
User action: None unless the calibration load fails or RSC communications fail. If
the problem persists, contact Adept Customer Service.
Searching for string (exact case) (None)
Explanation: The SEE editor command 0’ has been entered. The editor is prepared
to search for the string indicated, in the search mode indicated.
User action: This is an informational message. You can use the Repeat command
to perform the indicated search, or you can use Find (or Change) to
initiate a new search (or replacement) operation. The EXACT
extended command controls the setting of the search mode.
Searching for string (ignoring case) (None)
Explanation: The SEE editor command 0’ has been entered. The editor is prepared
to search for the string indicated, in the search mode indicated.
User action: This is an informational message. You can use the Repeat command
to perform the indicated search; or you can use Find (or Change) to
initiate a new search (or replacement) operation. The EXACT
extended command controls the setting of the search mode.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for adept technology MV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the adept technology MV and is the answer not in the manual?

adept technology MV Specifications

General IconGeneral
Brandadept technology
ModelMV
CategoryController
LanguageEnglish