26
Common Terminology
ISOBUS Working Set—One or more ISOBUS modules that control an implement’s functionality.
Working Set Master (WSM)—Main module responsible for coordinating all communication between the UT and the
Working Set including loading of the Object Pool to the UT screen.
Object Pool—The graphic image presented to the user on the UT display. The Object Pool is sent to the UT by the ISOBUS
module.
μ
ATTENTION!: Before operating an ISOBUS implement with the display, read the operator’s manual provided by the
implement’s manufacturer and follow all safety information provided in the manual. When this display is used with
an ISOBUS implement, the information and functions on the display are provided by the implement ECU and are
the responsibility of the implement manufacturer.
Broadcast Display Speed (ISO GBSD)—Checking this box allows speed source currently being utilized by the display
to be broadcast over the ISOBUS to the implement ECU.
Broadcast GPS (J1939)—Checking this box allows GPS data being supplied by the GPS receiver to be broadcast over the
ISOBUS to the implement ECU.
Auxiliary Module Support—Checking this box allows the Ag Leader Auxiliary Input Module or Smart Switchbox, to be
used with ISOBUS ECUs that support AUX-N auxiliary functions.
Universal Terminal Functional Instance—Always set to 0 except when there are multiple UTs on the ISOBUS. Use to
change instance. Reboot Display.
Section/Rate Compatibility—This setting determines how often the Display target rate message is sent to the ISOBUS
ECU.
• When unchecked, the target rate message is only sent when it is changed on the display.
• When checked, the target rate message is sent at regular intervals. This is a non standard ISOBUS setting. Leave this
setting off unless ISOBUS ECU has an issue with the target rate resetting to zero on its own.
ECU Section Delays—Determines the manner in which mapping delays are handled with ISOBUS ECUs.
• When checked (default), mapping delays are determined by ISOBUS ECU and the “look-ahead” interval stored in the
Ag Leader display. Leave this checked when using DirectCommand Gen2 ISO Liquid.
• When unchecked, mapping delays are determined by the “look-ahead” interval stored in the Ag Leader display. This
method is thought of as industry standard and is used by various manufacturers. Leave this unchecked when on
ground AutoSwath performance is correct but display mapping is showing gaps/overlaps.
÷
NOTE!: Enabling/disabling this setting does not effect on-ground section performance.
Enable File Server—Enables Hardi Sprayer specific diagnostic logging for troubleshooting purposes.
Task Controller Function Instance—Always set to 0 except when there are multiple TCs on the ISOBUS. Use to change
instance. Reboot Display.
ECU Section Look-Aheads—Determines how look-aheads are used for AutoSwath with ISOBUS ECU.
• When checked (default), the display will use look-ahead settings from the ISOBUS ECU.
• When unchecked, the display will use look-ahead settings that are entered and stored in the displays Automatic
Swath Control settings.
÷
NOTE!: Enabling/disabling this setting will effect on-ground section performance.