6 Interaction devices
mark the respective Flystick ID, e.g. F1’, by selecting it from the available Flysticks
list
mark the desired available Flystick and
press Select to finalize the assignment.
i
If the available Flysticks list doesn’t contain your Flystick although it
is already present, just press any button of the Flystick to register it at
the radio transceiver.
Repeat these steps if you want to use another Flystick.
i
There are two predefined entries for Flystick1 in the list available Fly-
sticks, even if no Flystick1 is present in the volume. This is due to
the fact that the Flystick1 connects via serial COMport which cannot
be polled automatically. If you are using a Flystick1 please refer to the
Flystick1 manual.
Inside the dialogue you can also configure the following settings for your Flystick:
Checkbox Description
use old output format Use the output format of the Flystick1 (see chapter
B on page 250)
activate MultiUser function Refer to page 82 in chapter 6.1 on page 71 for more
information.
use head targets The data pair (Flystick and head target) of one user
is made available as output data (if MultiUser func-
tion is activated).
Option (active Flystick3
only)
Description
sync groups Configure your active Flystick3 (discontinued) to
send out IR flashes for one or more syncgroups
(syncgroup #1, syncgroups #1 and #2, . . . ; default =
syncgroup #1).
flash intensity Change the flash intensity of the active target (dis-
continued) of the Flystick3 (default = 3) by moving
the slider.
Table 6.4: Flystick settings - Description of the checkboxes and options
MultiUser option The MultiUser option is an enhancement especially for VR/AR appli-
cations when working with more than one Flystick. Up to ten users can be equipped with
a Flystick and a head target (usually mounted on glasses). The software DTrack2 is able
to track them all but only the data pair (Flystick and head target) of one user is available
as output data. Switching between the single users can be done by just pressing one of
the Flystick buttons.
Depending on how many Flysticks you are using, you have to configure the number of
82