3.4.2 Electrical data of the BM53XX
m Double axis unit safety
Footnotes refer to Zpage 76–.
BM5323 BM5323-A BM5325 BM5325-A
Input rated power
1) 9)
3.5kW 5.75kW 7.0kW 9.9kW
Input rated current
1) 9)
5.5A 9A 11A 15.5A
DC link voltage (U
DC
)
1)
60 V - 760 V
DC link capacitance (internal) 235 µF
DC link discharge time
(internal DC link capacitance)
250 s
Output voltage
(U
AC
)
1) 3)
0 - 500 V
Output frequency at 4 kHz
4)
0 - 450 Hz
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
4kHz
4)
2x3A 2x4.5A 2x6A 2x8.5A
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
8kHz
4)
2x2.1A 2x3.15A 2x4.2A 2x5.9A
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
16 kHz
4)
-
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
4kHz
4)
2x9A 2x18A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
8kHz
4)
2x6.3A 2x12.6A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
16 kHz
4)
-
Short-time operation KB 300 % 200 % 300 %
Max. length of time peak current
6)
Refer to ZLoad cycle according EN61800-6– as from page 78
Power loss with regard to power supply Max. 55 W Max. 82.5 W Max. 100 W Max. 141 W
Power loss with regard to control voltage supply
(air-cooled)
7)
Max. 35 W
Power loss with regard to control voltage supply
(cold plate cooling)
7)
Max. 35 W
Current of the integrated brake control
(option)
8)
Max. 2 x 2.0 A
Cooling air requirement power heat sink 15 m
3
/h - 15 m
3
/h -
Cooling air velocity power heat sink - > 5 m/s - > 5 m/s
Cooling air requirement internal space of device - 10 m
3
/h
with cold plate
-