3.4
106.52 Resolver phase synchronization
Setting of the phase shifting of the resolver tracks dependent on the DSP interrupt. Then
bit 4 of
Z106.43– still must be activated.
Configuration examples:
– Z106.43– = 0x0003: Resolver standard setting, resolver frequency = 7.8125 kHz
without synchronization on the fieldbus with automatic amplitude and phase setting
– Z106.43– = 0x0083: Resolver reevaluation, resolver frequency = = 7.8125 kHz
without synchronization on the fieldbus with automatic amplitude and phase setting
_________________________________________________________________
– Z106.43– = 0x0093: Resolver reevaluation, resolver frequency = 8 kHz with syn-
chronization on the fieldbus and automatic amplitude and phase setting
Here the required phase shift to the DSP interrupt with >106.52< can be set.
– Z106.43– = 0x0092: Resolver reevaluation = 8 kHz with synchronization on the
fieldbus. However, with an automatic phase setting and an manual amplitude set-
ting. Here the following procedure shall be complied with:
1. Setting of Z106.20– (Z106.21–) = 0 and Z106.22– (Z106.23–) = 1024.
2. Set the excitation set-amplitude manually by Z106.44–, until the value is
displayed at Z14.3– by about 85%.
3. Set the required phase shifting to the DSP interrupt by >106.52<.
106.60 SSI mode
Setting of transmission and the data format:
Bit Meaning
9 ... 0 Reserved
13 - 10 Baud rate
Value Meaning
0 100 kHz
1 199 kHz
2 399 kHz
3 1,014 MHz
4 1,974 MHz
5 ... 15 Reserved