Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
214
of 814
3.4
131.10 Slave info
Current Slave Information.
131.11 MAC Address
Display of the MAC address for all Ethernet based fieldbuses supported by Baumueller
as: EtherCAT, POWERLINK, VARAN, Profinet-IRT.
131.12 Base IP address
If Slave Settings Z131.9 Bit 0 = 1, the IP address is determined from:
Base IP address + DIP-switch settings (Z131.13)
131.13 DIP switch settings
Setting on the DIP-switch used as an offset to the base IP address when Slave Settings
Z131.9 Bit 0 = 0.
15 Reserved
16 1: Switch off of the offset calculation for the objects 0x6062, 0x6064,
0x607A, 0x607C, 0x607D (UNSIGNED = SIGNED + 0x80000000)
31 ... 17 Reserved
Bit # Description
Bit # Description
1 ... 0 Fieldbus status:
0 – Init
1 – PreOperational
2 – SafeOperational
3 – Operational
In SafeOperational, the actual values are applicable. In Operational, the set
value and actual values are applicable.
7 ... 2 Reserved
23 ... 8 Fieldbus status code:
The current AL Status Code is displayed at EtherCAT
31 ... 24 Reserved