3.4
11 Selection Signal Level for qualification
0: Zero pulse trigger active when digital input = low
1: Zero pulse trigger active when digital input = high
12 Trigger frequency
0: one-time trigger
a new measure does not occur until measuring encoder has been reac-
tivated with P124.2
1: Continuous triggering
Measurements always occur; however, within a sampling cycle of the
module (1
ms), only the first event will be triggered.
13…
14
Reserved
15 Activation filter 500 µs for measuring encoder digital input TP1 (effects only for
measuring encoder, to all encoder)
1: Filtering with 500 µs
0:No filtering (-> 4 µs)
Encoder 2
16…
18
Measurement "Encoder 2 with Trigger digital input TP1"
16 Activation channel measurement positive edge
(Enc2TrDi1PosValRev/Enc2TrDi1PosValPhi)
0: switch off
1: switch on
17 Activation channel measurement negative edge
(Enc2TrDi1NegValRev/Enc2TrDi1NegValPhi)
0: switch off
1: switch on
18 Trigger frequency
0: one-time trigger
a new measure does not occur until measuring encoder has been reac-
tivated with P124.2
1: Continuous triggering
Measurements always occur; however, within a sampling cycle of the
module (1
ms), only the first event will be triggered.
19…
21
Measurement "Encoder 2 with Trigger digital input TP2"
19 Activation channel measurement positive edge
(Enc2TrDi2PosValRev/Enc2TrDi2PosValPhi)
0: switch off
1: switch on
20 Activation channel measurement negative edge
(Enc2TrDi2NegValRev/Enc2TrDi2NegValPhi)
0: switch off
1: switch on