Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
274
of 814
3.4
If only the function of all logic operations is switched off via the Z165.1 Mode bit 1 = 0,
the status of the logic operation outputs (bit no. 16 to 30) is frozen only.
165.3 Source numbers
This is a RECORD type parameter (array). This parameter contains the numbers of all 16
source parameters.
As soon as a valid parameter number is parameterized, the channel for the relevant sta-
tus bit of Z165.2 is released.
Bit No. Meaning
15 ... 0 Status of bits from the source parameters
Bit 0: Status Bit Source 0 Z165.3 Index 0
Bit 1: Status Bit Source 1 Z165.3 Index 1
Bit 2: Status Bit Source 2 Z165.3 Index 2
….
Bit 15: Status Bit Source 15 Z165.3 Index 15
30 ... 16 Results from the logic operations of the status bits:
Bit 16 Result from Bit 0 and 1
Bit 17 Result from Bit 2 and 3
Bit 18 Result from Bit 4 and 5
Bit 19 Result from Bit 6 and 7
Bit 20 Result from Bit 8 and 9
Bit 21 Result from Bit 10 and 11
Bit 22 Result from Bit 12 and 13
Bit 23 Result from Bit 14 and 15
Bit 24 Result from Bit 16 and 17
Bit 25 Result from Bit 18 and 19
Bit 26 Result from Bit 20 and 21
Bit 27 Result from Bit 22 and 23
Bit 28 Result from Bit 24 and 25
Bit 29 Result from Bit 26 and 27
Bit 30 Result from Bit 28 and 29
31 Reserved
Index Meaning
0 Source parameter for status bit 0 of Z165.2
1 Source parameter for status bit 1 of Z165.2
15 Source parameter for status bit 15 of Z165.2