EasyManua.ls Logo

Baumuller b maXX BM5800 - Page 286

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
286
of 814
3.4
179.14 Minimum software position limit
DS402 Factor Group object 0x607D.01 (negative limit switch for all position controlled op-
erating modes with position weighting corresponding to ZGeneral information from
page 277).
179.15 Maximum software position limit
DS402 Factor Group object 0x607D.02 (positive limit switch for all position controlled op-
erating modes with position weighting corresponding to ZGeneral information from
page 277).
179.16 Touch probe pos1 pos value
DS402 Factor Group object 0x60BA (touch probe value from revolutions and angle
scaled with position weighting corresponding to
ZGeneral informationfrom page 277).
Notice: The touch probe must be parameterized adequately, see notes on Zpage 281.
179.17 Touch probe pos1 neg value
DS402 Factor Group object 0x60BB (touch probe value from revolutions and angle
scaled with position weighting corresponding to
ZGeneral informationfrom page 277).
Notice: The touch probe must be parameterized adequately, see notes on Zpage 281.
179.18 Touch probe pos2 pos value
DS402 Factor Group object 0x60BC (touch probe value from revolutions and angle
scaled with position weighting corresponding to
ZGeneral informationfrom page 277).
Notice: The touch probe must be parameterized adequately, see notes on Zpage 281.
179.19 Touch probe pos2 neg value
DS402 Factor Group object 0x60BD (touch probe value from revolutions and angle
scaled with position weighting corresponding to
ZGeneral informationfrom page 277).
Notice: The touch probe must be parameterized adequately, see notes on Zpage 281.

Table of Contents