Management
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
300
of 814
3.5
Description of the bits for axis units
m Bit 0 to 3:
Control of the state machine for the drive. The device control commands are defined by
the following bit combinations:
Adapting transitions to the state machine
The bits labeled X have no significance for the corresponding command.
m Bit 4 - Ramp FG inhibit / New set value / Start reference run
n Speed Setting (Operating mode 2)
1: Enable ramp function generator
0: Inhibit ramp function generator (set output to 0)
n Speed Control (Operating mode -3)
Sense of the bits inverted with respect to the Speed Setting mode (Operating mode
2)
1: Inhibit ramp function generator (set output to 0)
0: Enable ramp function generator (enable output)
n Target Position Setting (Operating mode 1)
1: Start positioning if control of positioning is via "New Set Value"
n Reference run mode (Operating mode 6)
1: Start reference run
n Coupled operation (operation mode -12)
0->1 Activate switchover to a reloaded curve
m Bit 5 - Ramp FG Stop / Change set immediately:
n Target Position Setting (Operating mode 1)
Change set immediately
This bit is dependent on the setting in Parameter Z118.2,
Mode bit 11 active low or active high.
Z118.2 Mode Bit 11 = 0:
Command Bit 7
Reset
Error
Bit 3
Enable
Operation
Bit 2
Quick
Stop
a)
a)
These bits are active low.
Bit 1
Inhibit
Voltage
b)
b)
These bits are active low.
Bit 0
Switch
On
Transi-
tions
Shut Down X X 1 1 0 2, 6, 8
Switch On X X 1 1 1 3
Inhibit Voltage X X X 0 X 7, 9, 10,
12
Quick Stop X X 0 1 X 7, 10, 11
Inhibit Operation X 0 1 1 1 5
Enable Operation X 1 1 1 1 4, 5b, 8b,
16
Reset Error 0 1 X X X X 15