Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
413
of 814
3
154.3 Lower speed threshold
Lower speed limit (speed limit for the left-hand sided switching threshold)
154.4 Upper speed threshold
Upper speed limit (speed limit for the right-hand sided switching threshold)
154.5 Output value 1
Connected friction compensation value for
Speed < Lower speed limit
For connection „Three-point with hysteresis and dead zone“ (Z154.1– bit 2 ... 1 = 00) see
ZFig. 103– on page 408.
154.6 Output value 2
Connected friction compensation value for
Lower speed limit Speed < Upper speed limit
Effective only if connection „Three-point with hysteresis and dead zone“ (Z154.1–
bit 2 ... 1 = 00), see ZFig. 103– on page 408.
154.7 Output value 3
Connected friction compensation value for
Speed > Upper speed limit
For connection „Three-point with hysteresis and dead zone“ (Z154.1– bit 2 ... 1 = 00) see
ZFig. 103– on page 408.
NOTE!
The friction compensation must not used in combination with the torque coupling
function.