Structure of the parameter overviews
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
50
of 814
3.2
Example:
Number Z110.5 Functional block ramp function generator, parameter 5
Name Input 16 bit Name of parameter, display ProDrive English
Type INT Integer 16 bit
Min ... Max -16384 to 16384 Range of values
Default Value 0 Default value 0 at internal standardization
Unit % Unit % for ProDrive
Factor 4000
hex
: 100% 100% in ProDrive correspond to 16384 internal
The parameter is writable, cyclic writable (fieldbus cycle time < 1 ms), it will be stored
namely in all data sets; it is NOT axis independent, i.e. it can be set separately for each
axis.
Number Name Type Min Max Default Value Unit Factor
Read only
Storage
DS Support
Cyclic Write
Axis-independent
110.5 Input 16 bit INT -16384 16384 0 % 4000
hex
:
100%
X X X