3.8
Example of a changeover of a transmission ratio from 0.8 to 1.15:
– Application of the Transparent Mode (Z145.2– Mode bit 4 = 0):
– or change slave axis revolutions first:
– Application of the Edit Mode (Z145.2– Mode bit 4 = 1):
No undesired transmission ratios occur in Edit Mode!
i Z145.4– Rot. Master axis Z145.3– Rot. Slave axis
0.2 10 2
- 0.78 100 - 78
3.15 100 315
6.54321 100000 654321
0.3333 10000 3333
Rot. Master axis Rot. Slave axis Mode bit 4 Transmission
Ratio i
10 8 0 0,8
10 100 8 0 0.8 0.08
100 8 115 0 0.08 1.15
Rot. Master axis Rot. Slave axis Mode bit 4 Transmission
Ratio i
10 8 0 0,8
10 8 115 0 0.8 11.5
10 100 115 0 11.5 1.15
NOTE!
Undesired transmission ratios may occur in the Transparent Mode!
Rot. Master axis Rot. Slave axis Mode bit 4 Transmission
Ratio i
10 8 0 0.8
10 8 0 1 0.8
10 100 8 1 0.8
100 8 115 1 0.8
100 115 1 0 0.08 1.15