(7) After the second measurement, the machine displays the measured voltage on the LCD.
Using the volume shown in the figure below, adjust the displayed voltage so that it
becomes within the range of 0.40 to 0.60 V. After the adjustment, press the Go button.
Fig. 5-5
(8) The machine displays "PLZ Power OFF" on the LCD and stores the history of executed
adjustments in the EEPROM. Turn the power OFF.
Maintenance drive PCB ASSY
Volume