2-37
Confidential
■ Error code 0D00
Unable to save data because there is no space in the storage data area of memory.
<User Check>
- Delete the data of secure print, personal print, or public print that is stored in the machine.
■ Error code 0D01
Failed to read/write data in the storage I/O.
<User Check>
- Turn OFF and ON the power switch.
- Delete error indication by the following procedure.
(1) Press the Menu button at ready state.
(2) Press the button three times to select the "General Set Up" and press the OK button.
(3) Press the button nine times to select the "Macro / Font" and press the OK button.
(4) Press the button and Cancel button at the same time. * "Format Stage" is displayed.
* When pressing the button and Cancel button at the same time does not work the
machine operates even by pressing the Cancel button soon after pressing the button.
(5) Press the 1 button. "Format OK?" is displayed on the LCD.
(6) Press the 1 button again. "Formatting" is displayed on the LCD and error is cancelled.
Storage Full
There is no space in the Memory.
Step Cause Remedy
1 Malfunction of USB storage
memory
Format the USB storage memory.
2 USB storage memory failure Replace the USB storage memory.
3 Main PCB failure Replace the main PCB ASSY.
Storage Error.
To use other functions, press GO. Refer to the User's Guide for instructions
on correcting the Storage Error.
Step Cause Remedy
1 USB storage memory failure Replace the USB storage memory.
2 Main PCB failure Replace the main PCB ASSY.