4
4
4-369
4-369
Disassembly/Assembly > Pickup And Feeding System > Removing the Pickup Solenoid (MF4780w/MF4770n/MF4750/MF4730) > Procedure
Disassembly/Assembly > Pickup And Feeding System > Removing the Pickup Solenoid (MF4780w/MF4770n/MF4750/MF4730) > Procedure
x2
[1]
[2][3]
2)Disconnect the terminal[1], free the harness[2] from the harness guide[A], and then put it
through the hole[B].
[1][2]
[A]
[2] [B]
F-4-1008
F-4-1009
Caution:
When connecting the terminal[1], be sure that the contact spring[2] is in contact with
it.
[2]
[1]
F-4-1010
3)Remove the harness retaining spring[1] from the hook[2], and free the harness[3] from the
guide[A].
[1]
[2]
[3]
[A]
F-4-1011