Site Selection Guidelines
The Cisco ASR 1000 Series Routers require specific environmental operating conditions. Temperature,
humidity, altitude, and vibration can affect the performance and reliability of the router. The following sections
provide specific information to help you plan for the proper operating environment.
The Cisco ASR 1000 Series Routers are designed to meet the industry EMC, safety, and environmental
standards described in the Regulatory Compliance and Safety Information for the Cisco ASR 1000 Series
Aggregation Services Routers document.
Site Environmental Requirements
Environmental monitoring in the Cisco ASR 1000 Series router protects the system and components from
damage caused by excessive voltage and temperature conditions. To ensure normal operation and avoid
unnecessary maintenance, plan and prepare your site configuration before installation. After installation, make
sure the site maintains the environmental characteristics as shown in the following table.
Table 40: Cisco ASR 1000 Series Router Environmental Tolerances
MaximumMinimumEnvironmental Characteristic
50 degree C
(50 degrees C at 10,000 feet)
0 degree CSteady State Operating
+70 degrees C
20 degrees C
Storage
90%10%Humidity operating
(noncondensing)
95%5%Humidity nonoperating
(noncondensing)
10,000 feet
500 feet
Altitude operating: over allowable
temperature range (0 to 50 degrees
C)
50,000 feet
1000 feet
Altitude, nonoperating: over
allowable temperature range
+70 degrees C
25 degrees C
Thermal shock non-operating with
change over time of 3 minute
+50 degrees C0 degrees CThermal Shock - Operating at 2.5
degree C per minute
Cisco ASR 1000 Series Router Hardware Installation Guide
119
Preparing Your Site for Installation
Site Selection Guidelines

Table of Contents

Other manuals for Cisco ASR 1002-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1002-X and is the answer not in the manual?

Cisco ASR 1002-X Specifications

General IconGeneral
Form FactorRack-mountable
Rack Units2RU
Integrated ServicesYes
Maximum Memory16 GB
Built-in Gigabit Ethernet Ports6
Input Voltage100-240 VAC
Operating Temperature32 to 104°F (0 to 40°C)
RedundancyPower supply redundancy
Network Interface ModulesUp to 4 SPA/SIP slots
Embedded Services Processor (ESP)ESP-20
Maximum Packet per Second (PPS)15 Mpps
Height3.5 inches
Fixed Ports6 GE ports
Memory4 GB (default), 16 GB (maximum)
Power SupplyDual power supplies (AC or DC)
Dimensions (H x W x D)3.5 x 17.5 x 19.0 in (8.9 x 44.5 x 48.3 cm)