DVP-15MC Series Motion Controller Operation Manual
11-336
DMC_MoveDirectRelative
FB/FC
Explanation Applicable model
FB
DMC_MoveDirectRelative is used to control the axes in an axes
group to move corresponding distances from current positions at
specified velocities.
DVP15MC11T
DVP15MC11T-06
DMC_MoveDirectRelative
AxesGroup Done
DMC_MoveDirectRelative_instance
Execute
Distance
Busy
Active
CommandAborted
CoordSystem
BufferMode
TransitionMode
TransitionParameter
Error
ErrorID
Input Parameters
AxesGroup
The axes group
number
USINT
(The variable value
Execute
changes from
Execute
executed when
Execute changes from
FALSE to TRUE.
BOOL
TRUE or FALSE
(FALSE)
Distance
Set the distances that
axes move
ARRAY [1..8]
OF LREAL
negative number
(0)
When Execute
changes from
FALSE to TRUE.
BufferMode
mode between two
axes group
instructions
1:Buffered
MC_Buffer_Mo
de
1: mcBuffered
When Execute
changes from
FALSE to TRUE.
TransitionMode
mode between two
axes group
instructions
0:No transition curve
MC_Transition
_Mode
0: mcTMNone
When Execute
changes from
FALSE to TRUE.
TransitionParamet
er
parameter for specific
transition mode
LREAL
Positive number, 0
(0)
changes from
Note:
1. The execution of DMC_MoveDirectRelative instruction starts when Execute changes from FALSE to
TRUE. Changing Execute from TRUE to FALSE during the instruction execution will have no impact
on the instruction execution.
2. The value of input parameter Distance[1] ~ Distance[8] means the motion distances from start