DVP-15MC Series Motion Controller Operation Manual
8-256
_8
8.14.3.7 RS485_SetDelayTime
FB/FC Explanation
Applicable model
FB
RS485_SetDelayTime sets the response-delay time at the RS485
communication port of the controller.
DVP15MC11T
DVP15MC11T-06
RS485_SetDelayTime_Instance
RS485_SetDelayTime
ErrorID
Error
Done
DelayTime
Execute
Input Parameters
Parameter name Function Data type
Valid range
(Default)
Validation
timing
Execute
The instruction is executed when
Execute changes from FALSE to
TRUE.
BOOL
TRUE or FALSE
FALSE
-
DelayTime
The response-delay time at the
RS485 communication port of the
controller. It is valid n
o matter
whether the controller serves
as
a master or a slave. (Unit: ms)
UINT
0~65535
0
When
Execute
changes to
TRUE
Output Parameters
Parameter name Function Data type Valid range
Done
TRUE when the instruction execution is completed. BOOL
TRUE / FALSE
Error
TRUE when there is an error. BOOL
TRUE / FALSE
Error ID
Contains error codes when an error occurs. Please refer
to section 12.2 for the corresponding error code.
WORD
Output Update Timing
Parameter Name
Timing for changing to TRUE Timing for changing to FALSE
Done
When the instruction execution is
completed.
When Execute changes from TRUE
to FALSE
Error
When an error occurs in the instruction
execution or the input parameters for the
instruction are illegal.
When Execute changes from TRUE
to FALSE