5.2.3 Environmental Temperature in the Control Cabinet
Requirements
The ambient temperature of the motion controller inside the control cabinet is 0~55°C and the
humidity is 5 ~ 95%.
Please avoid making the installation near the high-temperature equipment.
Keep enough space for air ventilation.
The fan or air conditioner must be installed if the environment temperature exceeds 55°C.
The motion controller is for indoor use only.
The control cabinet which is 1.0m~2.0m in height is easier for installation and operation.
Keep the installation away from the high-voltage equipment and power equipment.
The power supply in the control cabinet must be cut off before installation.
5.2.4 Actions for Anti-interference
Do not install the controller in the control cabinet which contains high-voltage equipment.
Please keep at least 200mm far away from the power wire for the installation.
There should be a grounding wire for the control cabinet.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by
the equipment may be impaired.