5
Configuring the Operating Mode
5-5
Configuring the Switch
Figure 5-3 Configure Operating Mode Dialog Box
3. Select either Open Systems or S/390.
If you select Open Systems, set Interoperability Mode as
follows:
Select McDATA Fabric 1.0 if all switches in the fabric are in
this list:
ED-1032
ED-64M
DS-32M
DS-32M2
DS-16M
DS-16M2
Select Open Fabric 1.0 if one or more switches in the fabric are
not in the above list.
4. Click Activate to save the configuration and close the window.
5. Set the switch on line.
a. Click Maintenance on the Product Manager menu bar and
select Set Online State on the drop-down menu.
b. On the Set Online State window, click Set Online.
6. If you are finished configuring the switch, back up the
configuration data. For more information, refer to Backing Up and
Restoring the Configuration on page 7-12.