C-12 Connectrix DS-32M2 User Guide
Configuring the Switch from a Web Server
Figure C-6 Web Server Interface Configure Switch Operating Parameters
3. Configure the parameters as follows:
BB_Credit 1 through 16.
R_A_TOV 10 through 1200 (tenths of a second). (This
translates to a range of 1 through 120 seconds.) The default is
100 tenths, or 10 seconds.
If the switch is attached to another switch/director, both units must
be set to the same R_A_TOV. If the values are not identical, the port
connection segments and the switch cannot communicate with the
fabric. In addition, the R_A_TOV must be greater than the E_D_TOV.
E_D_TOV 2 through 600 (tenths of a second). (This
translates to a range of 0.2 through 60 seconds.) The default is
20 tenths, or 2 seconds.
If the switch is attached to another switch/director, both units must
be set to the same E_D_TOV. If the values are not identical, the port
connection segments and the switch cannot communicate with the
fabric. In addition, the E_D_TOV must be less than the R_A_TOV.
Preferred Domain ID 1 through 31. (The default is 1.)
Offline