A-24 Connectrix DS-32M2 User Guide
Using SNMP to Manage the Switch
FRU Group
ef6000SysOperStatus The current operational status of the switch. The values are defined as 
follows: operational (1), redundant-failure (2), minor-failure (3), major-failure 
(4), not-operational (5).
ef6000SysState If the edOperStatus of the switchis operational, the switch is in one of the four 
states: online(1), coming-online(2), offline(3), and going-offline(4).
ef6000SysAdmStatus
(read-write)
The desired administrative status of the switch. A management station may 
place the switch in a desired state by setting this object accordingly. The 
desired administrative statuses are online(1) and offline(2). Online means 
setting the switch to be accessible by an external Fibre Channel port, and 
offline means setting the switch to be inaccessible.
Table A-11 System Group (continued)
Variable Provides:
Table A-12 FRU Group
Variable Provides:
ef6000FruCode Field replaceable unit. A hardware component of the product that is replaceable 
as an entire unit. Each module defined in this MIB has a fixed FRU code. The 
values are defined as follows: fru-bkplane(1) - backplane; fru-ctp(2) - control 
processor card; fru-sbar(3) - serial crossbar; fru-fan2(4) - center fan module; 
fru-fan(5) - fan module; fru-power(6) - power supply module; fru-reserved(7) - 
reserved (not used); fru-glsl(8) - longwave, single-mode, LC connector, 1 Gig; 
fru-gsml(9) - shortwave, multi-mode, LC connector, 1 Gig; fru-gxxl(10) - mixed, 
LC connector, 1 Gig; fru-gsfl(11) - SFO pluggable, 1Gig; fru-gsf2(12) - SFO 
pluggable, 2 Gig; fru-glsr(13) - longwave, single-mode, MT-RJ connector, 1 Gig; 
fru-gsmr(14) - shortwave, multi-mode, MT-RJ connector, 1 Gig; fru-gxxr(15) - 
mixed, MT-RJ connector, 1 Gig; fru-fint1(16) - F_Port, internal, 1 Gig.
ef6000FruPosition Position of the module.
ef6000FruStatus Operational status of the module. The active(1) state indicates that the current 
module is active. The backup(2) state indicates that the backup module is used. 
The update-busy (3) state indicates that the module is in the updating process. 
The failed(4) state indicates that the current module is failed.
ef6000FruPartNumber Part number of the module.
ef6000FruSerialNumber Serial number of the module.
ef6000FruPowerOnHours Number of the hours that the FRU has been in operation.
ef6000FruTestDate Final test date of the module.