The Fcfporterrrortable displays the number of errors detected by an 
F_Port since the management agent initialized, enabling you to 
determine the quality of the link between the F_Port and its attached 
N_Port.
Table A-1 Error Group
Variable Provides the Number of:
fcFxPortErrorModuleIndex Module index for the module containing the F_Port for which this entry contains 
information.
This number ranges from 1 to AS_glob.prod_cnfg_ptr->max_nbr_modules. 
fcFxPortErrorFxPortIndex Port index, which identifies the F_Port within the module. This number ranges from 1 
to the value of fcFeModulePortCapacity for the associated module. The value remains 
constant for the identified F_Port until the module is reinitialized.
This number ranges from 1 to AS_glob.prod_cnfg_ptr->ports_per_module.
fcFxPortLinkFailures Number of link failures detected by the F_Port
fcFxPortSyncLosses Number of synchronization losses detected by the F_Port
fcFxPortSigLosses Number of signal loss errors detected by the F_Port
fcFxPortPrimSeqProtoErrors Number of primitive sequence protocol errors detected by the F_Port
fcFxPortInvalidTxWords Number of invalid transmission words detected by the F_Port
fcFxPortInvalidCrcs Number of invalid cyclic redundancy checks (CRC) detected by the F_Port
fcFxPortDelimiterErrors Number of delimiter errors detected by the F_Port
fcFxPortAddressIdErrors Number of address identifier errors detected by the F_Port
fcFxPortLinkResetIns Number of link reset protocol errors received by the F_Port from the attached N_Port
fcFxPortLinkResetOuts Number of link reset protocol errors issued by the F_Port to the attached N_Port
fcFxPortOlsIns Number of offline sequences received by the F_Port