Configuring Switch Ports
C-7
Configuring the Switch from a Web Server
Configuring Switch Ports
Perform the procedure in this section to configure names and
operating characteristics for the switch ports. Refer to Configuring
Ports on page 5-11 for more information on some of the parameters.
Figure C-3 shows the Configure window, opened to the default page.
Figure C-3 Web Server Interface — Configure Ports Window
1. Configure port parameters as follows. (Use the scroll bar at the
right of the window to display additional ports.)
• Name — Up to 24 alphanumeric characters. This name should
identify the device to which the port is attached.
• Blocked — Block/unblock transmission from a port by
clicking the checkbox to add/remove a checkmark.
• 10-100 km — Enable/disable extended distance buffering for
a port by clicking the checkbox to add/remove a checkmark.
2. Click Activate to save the information.