Connectrix DS-32M2 User Guide
Configuring the Switch
Figure 5-22 New Threshold Alerts Window — Second Screen
6. Enter a percentage for % utilization, 1 through 100. If throughput
reaches this percentage of port capacity, a threshold alert occurs.
7. Enter the amount of cumulative minutes in which the
% utilization should exist during the notification interval before
an alert is generated. You can also select At any time if you want
an alert to occur whenever the set % utilization is reached. The
valid range is 1 through the interval set in step 8.
8. Enter the interval (in minutes) during which throughput is
measured. The valid range is 5 to 70,560 minutes. When
throughput reaches the threshold value and remains constant for
the specified time, an alert is generated.
9. Click Next.
A new window appears for selecting ports for the alerts.