4
4-12
Connectrix DS-32M2 User Guide
Monitoring and Managing the Switch
• No response from an attached switch.
• ELP retransmission failure timeout — A switch with a
hardware or link failure attempted to join the fabric and
transmitted multiple ELP (exchange link protocol) frames to
another switch. The failed switch did not receive responses to
the ELP frames and did not receive an FLOGI frame.
◆ Threshold Alert — If a threshold alert exists for the port, an alert
indicator (yellow triangle) appears by the Threshold Alert field,
and the configured name for the last alert received appears in the
field.
Displaying Switch
Properties
To display a Switch Properties window, double-click the switch
illustration, away from a FRU (or right-click the switch illustration
away from a FRU and click Properties on the pop-up menu).
The Switch Properties window displays:
◆ Switch name, description, location, and contact, as configured
through the Configure Identification dialog box
◆ Fibre Channel WWN identifier for the switch
◆ Product type number
◆ Product model number
◆ Product manufacturer
◆ Product serial number
◆ Engineering change (EC) level
◆ Firmware level
◆ Operating mode: Open Systems or S/390
◆ Preferred Domain ID (set through the Configure Operating
Parameters dialog box).
◆ Active Domain ID (the actual Domain ID assigned to the switch)
◆ CTP state (active or inactive)
◆ Switch Speed (1 Gb/s or 2 Gb/s)