Ê Install the heat sink, see section "Installing the heat sink" on page 220.
Ê Install all expansion cards see section "Expansion cards and riser cards" on
page 170.
I Make sure that you reinstall each card in the slots it was located
before the replacement.
Ê "Reassembling" on page 52
Ê "Connecting the server to the mains" on page 55
Ê Connect all external cables.
Ê "Updating or recovering the system board BIOS and iRMC" on page 71
Ê If applicable, activate TPM functionality in the system BIOS under Security >
TPM (Security Chip) Setting > Security Chip. For more information, refer to the
corresponding BIOS Setup Utility reference manual.
Ê "Verifying system information backup / restore" on page 73
Ê If customer BIOS settings are not restored automatically, please change the
settings manually (using the information collected during "preliminary
steps"). If you couldn't determine the BIOS version, ask the customer to
reconfigure all BIOS settings and password.
Ê "Verifying the system time settings" on page 80
Ê "Looking up changed MAC / WWN addresses" on page 85
Ê "Updating the NIC configuration file in a Linux environment" on page 83
Ê "Enabling SVOM boot watchdog functionality" on page 78
Ê "Switching on the server" on page 57
Ê "Resuming BitLocker functionality" on page 84
Ê If applicable, reconfigure your network settings in the operation system
according to the original configuration of the replaced controller (expansion
card or onboard).
I Configuration of network settings should be performed by the
customer. For further information, please refer to section "Note on
network settings recovery" on page 277.
Ê If applicable, restore LAN teaming configurations as described in section
"After replacing the system board" on page 89