Page #73 background imageLoading...
Page #73 background image
RX1330 M1
Upgrade and Maintenance Manual 73
Basic software procedures
Ê The system will detect the USB stick.
I If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê Choose the Recovery_L option from the update tool menu to start the iRMC
update process.
V CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently corrupted.
I If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê Shut down the server by pressing the power On / Off button.
Ê Disconnect the server from the mains to exit the iRMC recovery state.
5.2.2 Verifying system information backup / restore
To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored from
the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the new
system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL) using the ServerView Operations Manager
(see also section "Viewing and clearing the System Event Log (SEL)" on
page 81).
After replacing the system board
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 81 to verify whether the backup data on
the Chassis ID EPROM has been restored to the system board:
Chassis IDPROM: BMC FW Restore successful
V CAUTION!
There might be a case that the BIOS settings cannot be restored even if
above message was logged after replacing the system board. For details
please refer to section "Replacing the system board" on page 276.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX1330 M1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX1330 M1 and is the answer not in the manual?

Fujitsu PRIMERGY RX1330 M1 Specifications

General IconGeneral
Number of Processors1
Memory Slots4
Maximum Memory32 GB
Form Factor1U Rack
ProcessorIntel Core i3 product family Intel Pentium product family
CPU FamilyIntel Xeon
Memory TypeDDR3 UDIMM
StorageUp to 4 x 3.5" or 2.5" drives
Drive Bays4
RAID0, 1, 5, 10
RAID ControllerOptional
Network2 x Gigabit Ethernet
Operating System SupportWindows Server, Red Hat Linux, SUSE Linux