EasyManuals Logo

Fujitsu Server PRIMERGY TX1330 M1 User Manual

Fujitsu Server PRIMERGY TX1330 M1
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
74 Upgrade and Maintenance Manual
TX1330 M1
Basic software procedures
Ê Burn the image to a DVD.
Ê In order to create a bootable USB stick, please proceed as described in
the "Local System Update for PRIMERGY Servers" user guide.
Ê Before using the ServerView Update DVD or USB stick in an offline
environment, properly shut down the server and disconnect all external I/O
connections (like LAN or FC cables) from the system. Only keep mouse,
keyboard, video cable and AC power cord connected.
I Ensure that all external I/O connections are uniquely identified so that
you can reconnect them into their original locations after concluding
the task.
To start Update Manager Express from the (physical) Update DVD or from a
USB stick, proceed as follows:
Ê Prepare your Update DVD or USB stick as described in the "Local System
Update for PRIMERGY Servers" user guide.
Ê Boot the server from the prepared Update DVD or USB stick:
DVD: Ê Switch on the server.
Ê Right after switching on the server, insert the Update DVD into the
DVD drive and close the tray.
USB: Ê Connect the USB stick to the server.
Ê Switch on the server.
If the server does not boot from DVD or USB stick, proceed as follows:
Ê Reboot the server, e.g. by pressing the reset button on the front or
switching the server off and then on again after a few seconds.
Ê Once the server has been started, press [F12] to enter the boot menu.
Ê Use the Ê and Ë cursor keys to select your DVD drive or USB stick as
boot device and press [ENTER].
The server will now boot from the Update DVD or USB stick.
Ê After the boot process is complete, select your preferred GUI language.
The Update Manager Express main window will be displayed.
Ê Finish the intended maintenance task.
I For further information, refer to the "Local System Update for
PRIMERGY Servers" user guide.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Server PRIMERGY TX1330 M1 and is the answer not in the manual?

Fujitsu Server PRIMERGY TX1330 M1 Specifications

General IconGeneral
Memory Slots4
Form FactorTower
ChipsetIntel C226
Processor Sockets1
ProcessorIntel Pentium, Intel Celeron
RAID SupportRAID 0, 1, 5, 10
Drive Bays8 x 3.5-inch
Operating System SupportWindows Server, Red Hat, SUSE, VMware