214 Upgrade and Maintenance Manual
TX1330 M1
Main memory
Ê Align the notch on the bottom of the module with the crossbar in the slot (see
close-up).
Ê Press down on the memory module until the securing clips snap into the
cutouts at each end of the module (2).
10.3.3 Concluding steps
Ê "Installing the fan module" on page 152
Ê "Reassembling" on page 58
Ê "Connecting the server to the mains" on page 67
Ê "Switching on the server" on page 68
Ê If applicable, "Updating or recovering the system board BIOS and iRMC" on
page 76
Ê "Enabling SVOM boot watchdog functionality" on page 84
Ê If applicable, "Verifying the memory mode" on page 85
Ê "Enabling BitLocker functionality" on page 90
10.4 Replacing memory modules
10.4.1 Preliminary steps
Ê Identify the defective memory slot using the server management software.
Ê "Disabling BitLocker functionality" on page 69
Ê "Disabling SVOM boot watchdog functionality" on page 70
Ê "Locating the defective server" on page 43
Ê "Shutting down the server" on page 46
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Software: 5 minutes
Tools: tool-less

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Server PRIMERGY TX1330 M1 and is the answer not in the manual?

Fujitsu Server PRIMERGY TX1330 M1 Specifications

General IconGeneral
BrandFujitsu
ModelServer PRIMERGY TX1330 M1
CategoryServer
LanguageEnglish

Related product manuals