EasyManuals Logo

Fujitsu Server PRIMERGY TX1330 M1 User Manual

Fujitsu Server PRIMERGY TX1330 M1
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #208 background imageLoading...
Page #208 background image
208 Upgrade and Maintenance Manual
TX1330 M1
Expansion cards and backup units
9.5.7.3 Installing the new BBU
Ê Install the BBU as described in section "Installing a BBU" on page 197.
9.5.7.4 Concluding steps
Ê "Installing the fan module" on page 152
Ê "Reassembling" on page 58
Ê "Connecting the server to the mains" on page 67
Ê "Switching on the server" on page 68
Ê If applicable, "Updating RAID controller firmware" on page 80
Ê "Enabling SVOM boot watchdog functionality" on page 84
Note on BBU charging and calibration
The BBU may be deeply discharged due to extended storage time and wrongly
show as bad or defective in the ServerView RAID Manager.
In this case, the BBU will automatically enter a trickle charge cycle for recovery.
This initial charge may take up to 8 hours before the BBU will initiate a
recalibration cycle.
Ê Enter the ServerView RAID Manager and check the current BBU status.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Ê If the BBU is shown as bad or defective, do not power off the server for at
least 8 hours to allow the charge and calibration cycles to finish.
Ê If the BBU status does not change after 8 hours, please try to initiate the
recalibration process manually using the ServerView RAID Manager.
I If this procedure still does not fix the BBU status, please contact your
local Fujitsu customer service partner.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Server PRIMERGY TX1330 M1 and is the answer not in the manual?

Fujitsu Server PRIMERGY TX1330 M1 Specifications

General IconGeneral
Memory Slots4
Form FactorTower
ChipsetIntel C226
Processor Sockets1
ProcessorIntel Pentium, Intel Celeron
RAID SupportRAID 0, 1, 5, 10
Drive Bays8 x 3.5-inch
Operating System SupportWindows Server, Red Hat, SUSE, VMware

Related product manuals