140 Upgrade and Maintenance Manual
TX1330 M1
Hard disk drives / solid state drives
7.3.5 Replacing a 3.5-inch HDD module
V CAUTION!
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators on the HDD
module, as described in the operating manual of your server.
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
All HDD modules (drives) must be uniquely identified so that they can
be reinstalled in their original mounting locations later. If this is not
done, existing data can be lost.
7.3.5.1 Preliminary steps
Ê "Locating the defective server" on page 43
Ê If applicable, "Removing the HDD bay cover" on page 55
Ê Locate the defective HDD module as described in section "Local diagnostic
indicators on the front" on page 45.
Only applicable for removing intact HDD modules:
Ê Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Server PRIMERGY TX1330 M1 and is the answer not in the manual?

Fujitsu Server PRIMERGY TX1330 M1 Specifications

General IconGeneral
Memory Slots4
Form FactorTower
ChipsetIntel C226
Processor Sockets1
ProcessorIntel Pentium, Intel Celeron
RAID SupportRAID 0, 1, 5, 10
Drive Bays8 x 3.5-inch
Operating System SupportWindows Server, Red Hat, SUSE, VMware

Related product manuals