90 Upgrade and Maintenance Manual
TX1330 M1
Basic software procedures
5.2.13 Enabling BitLocker functionality
If BitLocker Drive Encryption has been disabled for maintenance purposes (see
section "Disabling BitLocker functionality" on page 69), it has to be re-enabled
to complete the service task.
I If BitLocker Drive Encryption has been disabled prior to replacing
components you won't be asked for a recovery key when rebooting the
server after the maintenance task. However, if BitLocker functionality has
not been disabled, Windows will enter recovery mode and ask you to
input recovery key for further booting.
Ê In this case, ask the system administrator to enter the recovery key in
order to boot the operating system.
Ê Ask the system administrator to enable BitLocker-protection on the
operating system drive, using the BitLocker setup wizard available either
from the Control Panel or Windows Explorer.
Ê Open Bitlocker Drive Encryption by clicking the Start button, clicking
Control Panel, clicking Security, and then clicking Bitlocker Drive
Encryption.
I Administrator permission required: If you are prompted for an
administrator password or confirmation, type the password or
provide confirmation.
Ê To enable a temporarily disabled BitLocker, click Turn On BitLocker.
Ê Follow the instructions in the BitLocker Setup wizard.
I For further information on how to enable BitLocker drive encryption,
please refer to the Microsoft Knowledge Base.
Fujitsu service partners will find additional information (also available in
Japanese) on the Fujitsu Extranet web pages.
5.2.14 Performing a RAID array rebuild
After replacing a hard disk drive that has been combined into a RAID array,
RAID rebuild will be performed completely unattended as a background
process.
Ê Ensure that the RAID array rebuild has started normally. Wait until the
progress bar has reached at least one percent.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Server PRIMERGY TX1330 M1 and is the answer not in the manual?

Fujitsu Server PRIMERGY TX1330 M1 Specifications

General IconGeneral
Memory Slots4
Form FactorTower
ChipsetIntel C226
Processor Sockets1
ProcessorIntel Pentium, Intel Celeron
RAID SupportRAID 0, 1, 5, 10
Drive Bays8 x 3.5-inch
Operating System SupportWindows Server, Red Hat, SUSE, VMware

Related product manuals