86 Upgrade and Maintenance Manual
TX1330 M1
Basic software procedures
I For detailed information on memory operation modes available for your
server, refer to section "Memory sequence" on page 210.
After replacing the defective module(s) the memory operation mode is
automatically reset to its original state. It is recommended to verify that the
operation mode has been correctly.
Ê Enter the BIOS.
Ê Select the Advanced menu.
Ê Under Memory Status verify that none of the memory modules are marked as
Failed.
Ê Save your changes (if applicable) and exit the BIOS.
I For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.
5.2.10 Verifying the system time settings
I This task only applies to Linux environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
If a Linux OS is used and the hardware clock has been configured as UTC
(Universal Time, Coordinated) in the operating system, the BMC local time may
not be mapped correctly.
Ê After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
I If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
Ê Enter the BIOS.
Ê Select the Main menu.
Ê Under System Time and System Date specify the correct time and date.
I By default, the system time set in the BIOS is RTC (Real Time Clock)
local time. If your IT infrastructure relies on universally accepted time
standards, set the System Time to UTC (Universal Time, Coordinated)
instead. Greenwich Mean Time (GMT) can be considered equivalent
to UTC.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Server PRIMERGY TX1330 M1 and is the answer not in the manual?

Fujitsu Server PRIMERGY TX1330 M1 Specifications

General IconGeneral
BrandFujitsu
ModelServer PRIMERGY TX1330 M1
CategoryServer
LanguageEnglish

Related product manuals